Sunday, March 24, 2019

Replaced RESIN and CALCITE.
Iron problems continued as detected via toilet reservoirs.
Noted a surge of iron on first opening J bath spigot.
Could this be a regeneration issue? Otherwise water appears good.
Replaced fine mesh resin. Valve appeared very clean.
Cleaned and replaced calcite. Valve appeared iron coated, but otherwise normal.
PotPerm and salt being utilized normally.
Will check programming information and valve cycling.

Sunday, February 3, 2019

notes

Prompted resin regeneration for last night, Saturday night, with tank having 750g or so remaining. Today water looks good and no detectable iron in J's reservoir. Could be resin is now clean. Could be that when all valves are set to regenerate that they step on each others scheduling or that just the resin valve gets stepped on. Should review all regeneration clock settings.

Saturday, February 2, 2019

Water mixed.
As of 2/2/19 water looks good and J's toilet reservoir has no signs of iron accumulation around Clorox tablet. Will next scheduled resin regeneration result in continued clean water or will it leave water with iron residue? This regeneration should occur around 2/4/19 or so, say Monday or Tuesday. So, I'll be checking every day, but by next weekend I should have a decision/results 2/9/19.
If a problem resurfaces should replace resin, clean valve, and review status of check valves. If it looks like trouble early I'll order resin right away. Should it be fine or regular mesh?

Saturday, January 26, 2019

Trouble Again

Water currently in the A range
After the media updates and manual regens our water was looking great for a few days, but after about five days, around 1/22/19 I noticed a bit of iron bleed through. All the toilet tanks being regularly used showed mild evidence of iron in the reservoir tank. So, I conducted a couple of manual softener regenerations with resin cleaning and water looks as stated above, A range.
I purchased two clear backup checkvalves. For the installed check valves the before filtration and after filtration pictures are somewhat alarming. But hey, shows the filters are doing their job.
The second clear check valve is plumbed before the water softener (due to the fact I have a T junction to provide unsoftened water to the kitchen and installed check valve was concerned the split-off might somehow unseat the softener resin). Three points, could the first valve be fouled? Now that I have backups I could replace it and see. Also, it's a bit surprising that my chlorine injection and retention leaves the water still looking like mud. I do have terrible water. Finally, is this pre-softener near pristine check valve suggesting that any iron bleed through is occurring in the softener? The iron my not be visible as the conditions are not the same as in a toilet retention tank (no chlorine tablet, less no flow conditiion). Even if it were to be interpreted this way it would still suggest that iron is making it to the water softener such that the softener is iron polishing the water. Purchased 50 lbs of calcite. Am currently deciding whether to replace resin before doing anything. Also, ordered two 25 lb salt block and am considering these as a backup/adjunct to pellet salt.
a) have backup clear pvc check valves
b) have calcite
c) ordered salt blocks
b) evaluating resin
Pre filtration and post...



Friday, January 18, 2019

Corrected

Water A+
The manual regenerations and media fills seemed to have corrected the problem.
Calcite needs filling.
Also, I'd still like to replace one check valve and I think I need a new bladder on my well pressure tank.
If a problem resurfaces I'll need to check for backwash leaks, as always, and inspect the first PVC check valve. Otherwise, confirm all media is topped off and manually regen as necessary.

Thursday, January 17, 2019

Trouble

Water C-
The last few days water in toilet tank (the reservoir part) has been dark brown and one toilet has been generating a gritty brown ring. I've never seen such a ring before.
Note that is is after six months of perfect water.
Today:
Do not hear any dripping down backwash lines
Do not note any flow indicators activating when they shouldn't be (which would suggest leaks)
Noted that one clear check valve has such brown water cannot tell if it is fouled.
Would be interesting to see if clarity of water clears with chlorine replenishment.
Cleaned resin twice with one cup Iron Out and manual regeneration.
Added 80 lbs salt
Added one gallon Clorox and water to stenner pump reservoir.
Added 76 oz pot perm to each reservoir.
Noted that calcite/corosex is mostly depleted.


Thursday, August 16, 2018

Installed new Stenner Pump Tube yesterday after tear failure.
Water continues at consistent A+.
Check valves likely were important in resolving intermittent problems.